產(chǎn)品詳情
簡單介紹:
戊胺CH3(CH2)3CH2NH2氣體檢測管105SD
戊胺CH3(CH2)3CH2NH2氣體檢測管105SD,戊胺CH3(CH2)3CH2NH2氣體檢測管105SD PENTYL AMINE 2-22ppm,日本光明理化工業(yè)株式會社從1947年開始,在氣體分析領(lǐng)域開拓了六十余年 , 形成了馳名于世的 ” 北川 ” 式氣體檢測管。
詳情介紹:
戊胺CH3(CH2)3CH2NH2氣體檢測管105SD
戊胺CH3(CH2)3CH2NH2氣體檢測管105SD,戊胺CH3(CH2)3CH2NH2氣體檢測管105SD PENTYL AMINE 2-22ppm,日本光明理化工業(yè)株式會社從1947年開始,在氣體分析領(lǐng)域開拓了六十余年 , 形成了馳名于世的 ” 北川 ” 式氣體檢測管。氣體快速分析法 ” 北川 ” 的歷史就是日本檢測管的歷史 。目前是世界上*大的檢測管生產(chǎn)廠家,也是日本**家通過美國SEI的認證,歐盟的認證的檢測管廠家。公司不僅有ISO9001:2000的認證,還獲得了環(huán)境管理的ISO14001的認證。北川式手動氣體采集器AP-20 備有采氣完成指示計 , 可以清楚的判明采氣是否完成 . • 有專門截留玻璃的截留槽 , 以防止檢測管割尖時玻璃片飛濺 . • 有采氣容積為 50 毫升和 100 毫升的兩段式制動卡 . • 采氣器極為小巧 , 并有便于攜帶的皮具包 。
Tube No.105SD
1. PERFORMANCE
1) Measuring range :1-20 ppm 0.2-1 ppm
Number of pump strokes 1(100ml) 5(500ml)
2) Sampling time :1 minute/1 pump stroke
3) Detectable limit :0.1 ppm(100ml)
4) Shelf life :3 years
5) Operating temperature :0~40℃
6) Reading :Direct reading from the scale calibrated by 1 pump stroke
7) Colour change :Pale purple→Pale Yellow
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:5% RSD-high:5%
3. CHEMICAL REACTION
By reacting with Phosphoric acid, PH indicator is discoloured.
2NH3+H3PO4→(NH4)2PO4
4. CALIBRATION OF THE TUBE
PERMEATION TUBE METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
20
18
16
14
12
10
8
6
4
2 1
100ml
ppm
GAS To pump
DEHUMIDIFIER
(White)
105SD AMMONIA
Substance Interference Coexistence
Amines Similar stain is produced. Higher readings are given.
(NOTE)
When the concentration is below 1 ppm, 2 to 5 pump strokes can be used to detemine the lower concentration.
Following formula is available for actual concentration.
Actual concentration=Reading value× 1
Number of strokes
1. PERFORMANCE
1) Measuring range :1-20 ppm 0.2-1 ppm
Number of pump strokes 1(100ml) 5(500ml)
2) Sampling time :1 minute/1 pump stroke
3) Detectable limit :0.1 ppm(100ml)
4) Shelf life :3 years
5) Operating temperature :0~40℃
6) Reading :Direct reading from the scale calibrated by 1 pump stroke
7) Colour change :Pale purple→Pale Yellow
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:5% RSD-high:5%
3. CHEMICAL REACTION
By reacting with Phosphoric acid, PH indicator is discoloured.
2NH3+H3PO4→(NH4)2PO4
4. CALIBRATION OF THE TUBE
PERMEATION TUBE METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
20
18
16
14
12
10
8
6
4
2 1
100ml
ppm
GAS To pump
DEHUMIDIFIER
(White)
105SD AMMONIA
Substance Interference Coexistence
Amines Similar stain is produced. Higher readings are given.
(NOTE)
When the concentration is below 1 ppm, 2 to 5 pump strokes can be used to detemine the lower concentration.
Following formula is available for actual concentration.
Actual concentration=Reading value× 1
Number of strokes
The KITAGAWA Gas Detector Tube System is a complete sampling and analysis system for determining hazardous gas and vapour concentrations quickly and easily. The KITAGAWA Gas Detector Tube System is comprised of an Air Sampling Pump and Precision Gas Detector Tubes.
The KITAGAWA air sampling pump reproducibly draws 100cc of sample air through the detector tube. All detector tubes are calibrated for a single pump stroke; there is no need for multiple volumes or stroke counters.
Each detector tube is formulated with high purity reagents that absorb and react with the target gas or vapour being measured. A colorimetric stain is created that is proportional in length to the concentration. For most tubes, the concentration is read directly off the measurement scale on each tube.
How To Use The KITAGAWA Gas Detector Tube System
Detector tubes are available to measure more than 200 different kinds of gases and vapours. For many gases and vapours, there are several concentration ranges available giving you the flexibility to measure both low and high concentrations without sacrificing precision.
How To Use The KITAGAWA Gas Detector Tube System
Detector tubes are available to measure more than 200 different kinds of gases and vapours. For many gases and vapours, there are several concentration ranges available giving you the flexibility to measure both low and high concentrations without sacrificing precision.
For specific information, please refer to the list of detector tubes.